CHEMTRONICS INC -- ELECTRO WASH C80, C16, C24, C240-4 -- 6850-00D000975
===================== Product Identification ===================== Product ID:ELECTRO WASH C80, C16, C24, C240-4 MSDS Date:01/01/1991 FSC:6850 NIIN:00D000975 === Responsible Party === Company Name:CHEMTRONICS INC Address:8125 COBB CENTER DR City:KENNESAW State:GA ZIP:30144 Country:US Info Phone Num:404-424-4888 Emergency Phone Num:404-424-4888/800-424-9300(CHEMTREC) CAGE:2M589 === Contractor Identification === Company Name:CHEMTRONICS INC Address:8125 COBB CENTER DRIVE Box:City:KENNESAW State:GA ZIP:30152 Country:US Phone:770-424-4888/800-645-5244 CAGE:21267 Company Name:CHEMTRONICS INC (CANCELLED USE 21267) City:HAUPPAUGE State:NY ZIP:11760 Country:US CAGE:2M589 ============= Composition/Information on Ingredients ============= Ingred Name:TRICHLOROTRIFLUOROETHANE (FREON 113) (SARA III) CAS:76-13-1 RTECS #:KJ4000000 Fraction by Wt: 70% Other REC Limits:NONE DETERMINED OSHA PEL:1000PPM/1250STEL ACGIH TLV:1000PPM/1250STEL9192 Ozone Depleting Chemical:1 Ingred Name:CARBON DIOXIDE CAS:124-38-9 RTECS #:FF6400000 Other REC Limits:NONE DETERMINED OSHA PEL:5000 PPM ACGIH TLV:5000PPM/30000STEL;93 Ingred Name:TRICHLOROFLUOROMETHANE (CFC-11) (SARA III) CAS:75-69-4 RTECS #:PB6125000 Other REC Limits:NONE SPECIFIED OSHA PEL:1000 PPM ACGIH TLV:C, 1000 PPM; 9293 EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ozone Depleting Chemical:1 ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:YES Health Hazards Acute and Chronic:INHALATION-VAPOR IS HEAVIER THAN AIR AND CAN CAUSE SUFFOCATION BY REDUCING OXYGEN AVALIABLE FOR BREATHING. EYE-LIQUID CONTACT CAN CAUSE DISCOMFORT. USUALLY NO EXTENDED EFFECT. ORAL-ALTHOUGH ORAL TOXIC ITY IS LOW, INGESTION IS TO BE AVOIDED.SKIN-REPEATED LIQUID CONTACT CAN CAUSE DEFATTING OF THE SKIN. Explanation of Carcinogenicity:COMPONENTS ARE NOT LISTED AS CARCINOGENS BY IARC OR NTP. OSHA REGULATED-YES; OSHA AIR CONTAMINANT. TOXIC-TES; LOW TOXIC Effects of Overexposure:INHALATION-BREATHING HIGH CONCENTRATIONS OF VAPOR CAN CAUSE LIGHT HEADEDNESS, GIGGINESS, SHORT OF BREATH & MAY LEAD TO NARCOSIS, CARDIAC IRREGULARITIES, UNCONSCIOUSNESS & DEATH. SKIN-IRRITATION OR RED NESS MAY OCCUR DUE TO DEFATTING. INGESTION-MAY CAUSE NAUSEA & VOMITING. EYE-CONTACT MAY CAUSE TEMPORARY DISCOMFORT. Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE. ======================= First Aid Measures ======================= First Aid:INHALATION:REMOVE TO FRESH AIR & CALL A PHYSICIAN. IF NOT BREATHING PERFORM CPR. IF BREATHING IS HARD GIVE OXYGEN. DO NOT GIVE EPINEPHRINE OR SIMILAR DRUGS. SKIN:FLUSH WITH WATER. INGESTION-NO SPECIFI C INTERVENTION IS INDICATED. HOWEVER, CONSULT A PHYSICIAN IF NEEDED. DO NOT INDUCE VOMITING DUE TO ASPIRATION HAZARD. EYE-IMMEDIATELY FLUSH WITH WATER FOR 15 MIN. SEEK MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point:NONE,AEROSOL Extinguishing Media:NONFLAMMABLE. Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS (SCBA) MAY BE REQUIRED IF CONTAINERS RUPTURE & CONTENTS ARE RELEASED UNDER FIRE CONDITIONS. Unusual Fire/Explosion Hazard:PRESSURIZED AEROSOL CONTAINERS MAY VENT, RUPTURE OR EXPLODE AND ADD TO FYLING AND FALLING DEBRIS. DECOMPOSITION MAY OCCUR. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA. REMOVE OPEN FLAMES OR OTHER SOURCES OF IGNITION.. COLLECT SPILLED PRODUCT WITH ABSORBENT MATERIAL AND PLACE IN CLOSED STEEL DRUMS FOR PROPER DISPOSAL. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT STORE NEAR SOURCES OF HEAT, IN DIRECT SUNLIGHT, OR WHERE TEMPERATURES EXCEEED 120F. DO NOT PUNCTURE OR DAMAGE CONTAINERS. ROTATE STOCK. Other Precautions:THIS PRODUCT CONTAINS THE FOLLOWING TOXIC CHEMICALS SUBJECT TO THE REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY PLANNING & COMMUNITY RIGHT TO KNOW ACT OF 1986: 70%, TRICHLOROTRIFLUOROETHANE, CAS# 76-13-1. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NO; GOOD VENTILATION/H.C. RESPIRATOR. Ventilation:NO; AS NEEDED TO COMPLY WITH TLV. Protective Gloves:YES; BUTYL GLOVES. Eye Protection:YES; CHEMICAL SPLASH GOGGLES. Other Protective Equipment:YES; EYE BATH AND PROTECTIVE CLOTHING. Work Hygienic Practices:NORMAL VENTILATION FOR STANDARD PROCEDURES; LOCAL EXHAUST FOR LARGE RELEASES; MECHANICAL VENTILATION IN LOW PLACES. Supplemental Safety and Health NOTE TO PHYSICAN: BECAUSE OF THE POSSIBLE INCREASED RISK OF ELICITING CARDIAC ADYSRYTHMIAS, CATECHOLINAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED ONLY AS A LAST RESORT IN LIFE THREATENING EMERGE NCIES. ================== Physical/Chemical Properties ================== HCC:V2 Boiling Pt:=23.9C, 75.F Vapor Pres:334 MMHG Vapor Density:4.6 @77F Spec Gravity:1.46 Evaporation Rate & Reference:>1 (BUTYL ACETATE=1) Solubility in Water:NEGLIGIBLE Appearance and Odor:COLORLESS LIQUID, FAINT SOLVENT ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ALKALI & ALKALINE EARTH METAL-POWDERED ALUMINUM, BERYLLIUM, ZINC, AND MAGNESIUM. Stability Condition to Avoid:AVOID SPRAYING NEAR OPEN FLAMES OR RED HOT SURFACES. DO NOT HEAT AEROSOL CONTAINERS ABOVE 120F/49C. Hazardous Decomposition Products:COMPOUND CAN BE DECOMPOSED BY HIGH TEMPERATURES FORMING HYDROCHLORIC & HYDROFLUORIC ACIDS & POSSIBLY CARBONYL HALIDES. ==================== Disposal Considerations ==================== Waste Disposal Methods:COMPLY WITH ALL FEDERAL, TATE, & LOCAL REGULATIONS. DO NOT PUNCTURE OR INCINERATE AEROSOL CANS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.