MAVIDON CORP -- COLLODION REGULAR -- 8010-00N050572
=====================  Product Identification  =====================

Product ID:COLLODION REGULAR
MSDS Date:01/01/1991
FSC:8010
NIIN:00N050572
=== Responsible Party ===
Company Name:MAVIDON CORP
Address:3953 SW BRUNER TERRACE
City:PALM CITY
State:FL
ZIP:34990
Country:US
Info Phone Num:800-535-5053
Emergency Phone Num:407-286-8951
CAGE:0EUM3
=== Contractor Identification ===
Company Name:MAVIDON CORP
Address:3953 BRUNER TERRACE
Box:City:PALM CITY
State:FL
ZIP:34990
Country:US
Phone:407-286-8951
CAGE:0EUM3

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHYL ALCOHOL; (SDA-3A). VP: 44@20C
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: >1%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM

Ingred Name:ETHYL ALCOHOL; (SDA-32 ANHY). VP: 44@20C
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: 20%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM

Ingred Name:ETHANE, 1,1'-OXYBIS-; (ETHYL ETHER). VP: 442@20C
CAS:60-29-7
RTECS #:KI5775000
Fraction by Wt: 70%
OSHA PEL:400 PPM
ACGIH TLV:400PPM;500 STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:PRLNGD/RPTD EXPOS BY INHAL OF VAP CONC
    IN EXCESS OF TLV &/OR BY SKIN CONT W/LIQ MAY CAUSE DAM TO NERV SYS,
    BLOOD & KIDNEYS. SYMPS INCL HDCH, LETHARGY, DROW, WEAK, DFCLTY
    WALKING, PERSONALITY CHANGE, P OOR APPETITE, NAUS & WT LOSS. VAP
    IRRITATING TO EYES, NOSE, & THROAT. LIQ IRRITATING TO EYES. REPORTS
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: HAVE ASSOC RPTD & PRLNGD OCCUP
    OVEREXP TO SOLV W/PERM BRAIN & NERV SYS DAM. INTENTIONAL MISUSE BY
    DELIB CONC & INHALING CONTENTS MAY BE HARMFUL/FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE TO FRESH AIR; IF NOT BRTHG, GIVE ARTF RESP; IF
    BRTHG IS DFCLT, GIVE OXYGEN. EYES: IMMED FLUSH W/PLENTY OF WATER
    FOR AT LST 15 MIN. SKIN: IMMED FLUSH WITH PLENTY OF WATER FOR @ LST
    15 MIN  WHILE REMOVING CONTAMD CLTHG & SHOES. GET MED ATTN. INGEST:
    CALL MD IMMED .

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:49.0F,9.4C
Lower Limits:3.3%
Upper Limits:36%
Extinguishing Media:EXTINGUISH FIRES WITH CO*2, WATER (F0G), STEAM,
    FOAM/DRY CHEMICAL. COOL FIRE EXPOSED METAL CONTRS W/WATER SPRAY.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. COOL
    DOWN MATL AFTER BLAZE IS STRUCK.
Unusual Fire/Explosion Hazard:WHEN EXPOSED TO HEAT & FLAME, MATL IS A
    FIRE & EXPLO HAZ. WHEN MATL IS INVOLVED IN A FIRE, TOX DEGRADATION
    PROD CAN BE PRDCD, INCL CO*2, CO, & OXIDES OF(SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELIM ALL SOURCES OF IGNIT & KEEP HOT METAL
    SURF ISOLATED FROM SPILL. FLUSH SPILLED MATL INTO SUITABLE
    RETAINING AREAS/CONTRS W/LG QTY OF WATER. SM AMTS OF SPILLED MAY BE
    ABSORBED INTO APPROP ABSORB.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP PROD & CONTRS COOL, DRY & AWAY
    FROM SOURCES OF IGNIT. USE & STORE PROD W/ADEQ VENT. KEEP CONTRS
    CLSD WHEN NOT IN USE.
Other Precautions:AVOID INHAL OF VAPS & PERSONAL CONT W/PROD. SHOULD
    CONT BE MADE, REMOVE SATURATED CLTHG AND FLUSH AFFECTED AREAS
    W/WATER. CEAN UP MATL THAT HAS DRIED BY USING NON SPARKING
    TOOLS/WASHING W/SOLVENT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE OF RESP PROT DEPENDS ON VAP CONC ABOVE
    TIME-WEIGHED TLV; USE OF NIOSH/MSHA APPRVD CARTRIDGE RESP/GAS MASK.
Ventilation:GEN MECH VENT MAY BE SUFF TO KEEP PROD VAP CONC W/IN
    SPECIFIED TIME WEIGHED TLV RANGE. SUPP LOC EXHST MAY BE REQD.
Protective Gloves:CHEMICALLY INERT GLOVES.
Eye Protection:ANSI APPVD CHEM WORK GOGG .
Other Protective Equipment:APRON. EMERG EYE WASH & DELUGE SHOWER WHICH
    MEET ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH: NEUTRAL TO SLIGHTLY ACIDIC. EXPLO HAZ: NITROGEN. DENSE SMOKE CAN BE
    PRDCD WHEN MATL BURNS. MATL TO AVOID: CONT W/DRIERS UNLESS
    AGITATION.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:94.0F,34.4C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.758
pH:SUPDAT
Solubility in Water:SOL/PARTIALLY SOL
Appearance and Odor:CLEAR TO SLIGHT HAZE; SOLVENT ODOR
Percent Volatiles by Volume:94.88

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTAM W/STRONG OXIDIZING AGENTS, STRONG ACIDS, STRONG BASES,
    CERTAIN AMINES. DO NOT ALLOW FILM TO COME (SUPDAT)
Stability Condition to Avoid:HEAT, SPARKS, SOURCES OF IGNIT, OPEN
    FLAMES.
Hazardous Decomposition Products:COMBUSTION CAN PRODUCE CARBON DIOXIDE
    AND/OR BURNS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF USED PROD & ABSORB IN COMPLIANCE WITH
    APPLIC LOC, ST, COUNTY & FED REGS REGARDING HLTH & ENVIRONMENT. HAZ
    LIQ MAY NOT BE DISPOSED OF IN LANDFILLS AND WILL REQUIRE
    INCINERATION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.