REMEL LIMITED PARTNERSHIP -- LUGOL'S IODINE, 21-697 -- 6505-00N058360
=====================  Product Identification  =====================

Product ID:LUGOL'S IODINE, 21-697
MSDS Date:04/12/1993
FSC:6505
NIIN:00N058360
=== Responsible Party ===
Company Name:REMEL LIMITED PARTNERSHIP
Address:12076 SANTA FE DR
Box:14428
City:LENEXA
State:KS
ZIP:66215
Country:US
Info Phone Num:913-888-0939
Emergency Phone Num:800-255-6730
CAGE:IO995
=== Contractor Identification ===
Company Name:REMEL LIMITED PARTNERSHIP
Box:UNKNOW
CAGE:3936X
Company Name:REMEL LIMITED PARTNERSHIP
Address:12076 SANTA FE DR
Box:14428
City:LENEXA
State:KS
ZIP:66215
Country:US
Phone:800-447-3641
CAGE:IO995

=============  Composition/Information on Ingredients  =============

Ingred Name:IODINE
CAS:7553-56-2
RTECS #:NN1575000
Fraction by Wt: 5.0%
OSHA PEL:C 0.1 PPM
ACGIH TLV:C 0.1 PPM; 9495

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:DANGER! POISON, MAY BE HARMFUL OR
    FATAL IF SWALLOWED. MAY CAUSE IRRITATION TO SKIN, EYES AND 
    RESPIRATORY TRACT. AVOID BREATHING VAPOR AND EYE OR SKIN CONTACT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING EYE, SKIN
    OR RESPIRATORY DISORDERS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF
    THIS SUBSTANCE.

=======================  First Aid Measures  =======================

First Aid:INHALATION: NOT APPLICABLE UNDER NORMAL CONDITIONS OF USE.
    SEEK MEDICAL ASSISTANCE IF NECESSARY. EYE: WASH IMMEDIATELY WITH
    COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. CALL PHYSICIAN.
    SKIN: WASH	IMMEDIATELY WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST
    15 MINUTES. REMOVE CONTAMINATED CLOTHING. CALL PHYSICIAN.
    INGESTION: CALL PHYSICIAN IMMEDIATELY.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE EXTINGUISHING MEDIA APPLICABLE TO SURROUNDING
    FIRE CONDITIONS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS HIGHLY TOXIC FUMES OF IODINE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR PROT CLOTHING & EQUIP SPECIFIED. WEAR
    SCBA/RESPIRATOR W/APPRVD NIOSH/MSHA CARTRIDGES, IF NEC. CONTAIN
    SPILL & FLUSH AREA WITH 1-5% SODIUM BISULFITE & H*2O SOLUTION.
    ABSORB W/INERT MATERIAL, SCOOP  UP & PLACE IN APPRVD HAZ WASTE
    CNTNR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Ventilation:MECHANICAL EXHAUST, FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE APRON OR GOWN AS REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOLUBILITY IN WATER: INSOLUBLE (SOLUBLE IN AQUEOUS IODINE SOLN)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:185F,85C
Melt/Freeze Pt:M.P/F.P Text:114F,45C
Vapor Pres:1 @ 107F
Spec Gravity:4.93
Evaporation Rate & Reference:>1 (ETHER=1)
Solubility in Water:(SUPDAT)
Appearance and Odor:VIOLET-BLACK CRYSTALS, METALLIC LUSTER.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG REDUCING AGENTS, STRONG ACIDS; MAY REACT WITH METALS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:IODINE FUMES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:ENSURE COMPLIANCE WITH ALL LOCAL, STATE, AND
    FEDERAL REGULATIONS OR CONTACT AN APPROVED AND LICENSED DISPOSAL
    AGENCY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.