CREST INDUSTRIES INC -- LIQUID RUBBER, BL-R -- 8030-00N086318
=====================  Product Identification  =====================

Product ID:LIQUID RUBBER, BL-R
MSDS Date:05/24/1988
FSC:8030
NIIN:00N086318
=== Responsible Party ===
Company Name:CREST INDUSTRIES INC
Address:3841 13TH ST
City:WYANDOTTE
State:MI
ZIP:48192
Country:US
Info Phone Num:313-283-4100
Emergency Phone Num:313-283-4100
CAGE:2L332
=== Contractor Identification ===
Company Name:CREST INDUSTRIES INC
Address:3841 13TH ST
Box:City:WYANDOTTE
State:MI
ZIP:48192
Country:US
Phone:313-283-4100
CAGE:2L332

=============  Composition/Information on Ingredients  =============

Ingred Name:TOLUENE (SARA 313) (CERCLA). BP:230F,110C. VP:38 @ 20C.
    EVAP RATE:1.5 (N-BUAC=1). FL PT:45F,7C. LEL:1.2%. UEL:7%.
CAS:108-88-3
RTECS #:XS5250000
OSHA PEL:200 PPM
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (VM&P NAPHTHA).
    BP:233F;112C. VP:<38 @ 20C. EVAP RATE:1 (N-BUTYL ACETATE=1). (ING
    3)
CAS:64742-47-8
RTECS #:OA5504000
OSHA PEL:N/K 
ACGIH TLV:300 PPM (MFR)

Ingred Name:ING 2:FL PT:45F,7C. LEL:0.9%. UEL:7%.
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPP DATA:& PRLNG OCCUP OVEREXP TO SOLVS W/PERM BRAIN &
    NERV SYS DMG. SYMPS INCL:LOSS OF MEMORY, INTELLECTUAL (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4:ABILITY & COORD. NOTE:INTENTIONAL MISUSE BY DELIB
    CONC & INHAL SOLV VAPS MAY BE HARMFUL/FATAL! SKIN:EXPOS (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:TO SM AMTS OF SOLV OVER LONG PERIODS OF TIME MAY
    CAUSE SOME/ALL OF SYMPS AS IN ACUTE EXPOS TO SOLVS. EYES: (ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:SYMPS AS IN ACUTE EXPOS BUT TO A LESSER DEGREE & DMG
    NOT LIKELY. INGEST:UNKNOWN. NOTE:TOLUENE APPEARS ON (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:THE NAVY LIST OF OCCUP CHEM REPRO HAZS. SEEK
    CONSULTATION FROM APPROP HLTH PROFESSIONALS CONCERNING LATEST (ING
    9)
RTECS #:9999999ZZ

Ingred Name:ING 8:HAZARD LIST INFORMATION & SAFE HANDLING & EXPOSURE
    INFORMATION .
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:FROM RISK OF FURTHER EXPOS. ADMIN OXYG/ARTF
    RESP AS NEEDED. OBTAIN MED ATTN. INGEST:INDUCE VOMIT.(ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:CONSULT MD, HOSPITAL, EMER ROOM/POIS CTL CTR IMMED.
    HAVE LIST OF INGS AVAIL. NOTES TO MD:EYES:STAIN FOR (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:EVID OF CORNEAL INJURY. IF CORNEA BURNED, INSTILL
    ANTIBIOTIC/STEROID PREPARATION FREQUENTLY. SKIN:TREAT (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:SYMPTOMATICALLY. INHAL:TREAT AS FOR SOLVENT FUME
    INHALATION. INGEST:INDUCE VOMITING.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:SOLV VAPS AT CONCS ABOVE
    TLV CAN IRRIT RESP TRACT (NOSE, THROAT, LUNGS) CAUSING BURNING
    SENSATION, RUNNY NOSE, SORE THROAT, COUGH, CHEST DISCOMFORT
    (TIGHTNESS). MAY CAUSE CNS DEPRESS W/FOL LOWING PROGRESSIVE
    SYMPS:HDCH, DIZZ, NAUS, STAG GAIT, CONFUSN, UNCON, CESSATION OF
    BRTHG & DEATH. SKIN:(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:RPTD/PRLNG CONT W/SOLVS CAN RSLT IN
    DRY, DEFATTED & CRACKED CAUSING INCR SUSCEPTIBILITY TO INFECTION.
    IRRIT MAY DEVEL INTO CONT DERM. EYE:SOLV FUMES MAY IRRIT
    W/RESULTING ITCH, BURNING, REDNE SS. PERM TISS DMG MAY OCCUR IF
    SEALANTSARE APPLIED DIRECTLY & NOT FLUSHED OUT IMMED. INGEST:IRRIT
    TO MOUTH, & (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFICALLY KNOWN TO MFR, BUT
    IT IS POSS THAT EYE, RESP TRACT, SKIN, LIVER, KIDNEY, BLOOD CELL
    FORM, NERV SYS & BRAIN DISEASES MAY BE AGGRAVATED BY OVEREXP TO
    PRODS ON THIS MSDS.

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/CLEAN, LUKEWARM WATER (LOW PRESS) FOR AT LST 15
    MINS WHILE LIFTING LIDS. REFER PERS TO MD FOR IMMED ATTN.
    SKIN:REMOVE CONTAM CLTHG IMMED. WIPE OFF EXCESS MATL W/RAGS/PAPER
    TOWELS. CLEAN W /WATERLESS HAND CLEANER/WASH AFFECTED AREAS THORO
    W/SOAP & WATER. WASH CONTAM CLTHG THORO BEFORE REUSE. APPLY SKIN
    CREAM IF IRRITATED. SEEK MED ATTN IF IRRIT PERSISTS. INHAL:MOVE TO
    AREA FREE (ING 10)

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:45.0F,7.2C
Lower Limits:SEE INGS
Upper Limits:SEE INGS
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
    WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED CNTNRS TO PREVENT
    PRESS BUILD-UP (CNTNRS MAY LEAK OR BURST).
Unusual Fire/Explosion Hazard:VAPS ARE HVR/AIR & MAY TRAVEL ALONG
    GROUND/BE MOVED BY VENT & IGNITED BY PILOT LIGHTS, OTHER FLAMES,
    SPKS, HEATERS, ELEC MOTORS, SMOKING/OTHER IGNIT (SUPP DATA)

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEAR PROT EQUIP INCL NIOSH APPRVD RESP PROT.
    PVNT FURTHER SPILLAGE. EVACUATE NONESSNTL PERS. REMOVE ALL SOURCES
    OF IGNIT & VENT AREA. KEEP SPILL FROM REACHING SEWERS & WATERWAYS.
    COLLECT MATL W/NONSPA RKING TOOLS & PUT IN TIGHTLY SEALED
    CNTNR.(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STOR TEMP:MIN-50F(10C); MAX-130F(54C).
    REC SHELF LIFE:1 YR. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME. DO NOT
    INHALE VAPS. AVOID CONT W/SKIN & EYES.
Other Precautions:DO NOT STORE IN TEMPS >130F(54C) OR IN DIRECT
    SUNLIGHT. EDUCATE & TRAIN EMPLOYEES IN SAFE USE & HNDLG OF THESE
    MATLS AS REQD UNDER OSHA HAZ COMMUNICATION STD (29 CFR 1910.1200).
    FOLLOW ALL LBL INSTRUC TIONS. KEEP OUT OF REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF EXHAUST VENT SUFFICIENT TO KEEP AIR-BORNE
    CONC OF SOLVS BELOW THEIR RESPECTIVE TLV'S IS NOT POSSIBLE, A NIOSH
    APPROVED TC23C RESPIRATOR OR TC-19C AIR SUPPLIED RESP MUST BE USED.
    OBSERVE OSHA REGS ( 29 CFR 1910.134) FOR RESPIRATOR USE.
Ventilation:THERE MUST ALWAYS BE ENOUGH VENTILATION TO KEEP VAPOR
    CONCENTRATION BELOW LOWER FLAMMABLE LIMIT!
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
    SHOWER . COVER AS MUCH OF SKIN AS POSSIBLE W/APPROPRIATE CLOTHING.
Work Hygienic Practices:WASH HANDS AFTER USE & BEFORE EATING, DRINKING,
    SMOKING OR USING TOILET. CONTACT LENSES SHOULD NOT BE WORN.
Supplemental Safety and Health
EXPLO HAZ:SOURCES AT LOCATIONS FAR FROM MATL BOILING POINT. AT ELEVATED
    TEMPS (130F(54C) OR OVER) CNTNRS MAY VENT, RUPTURE/BURST
    (CARTRIDGES MAY EXTRUDE THEIR PLUNGERS). SPILL PROC:REMOVE CNTNR TO
    SAF E PLACE. EFTS OF OVEREXP:IF SWALLOWED, TO ESOPHAGUS, STOM TISS
    & DIGEST TRACT. CHRONIC:INHAL:RPTS HAVE ASSOC RPTD(ING 4)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:SEE INGS
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SEE INGREDIENTS
Solubility in Water:<1% (WT).
Appearance and Odor:BLACK PASTE; MILD SOLVENT ODOR.
Percent Volatiles by Volume:35-40

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:STABLE UNDER NORMAL ROOM CONDITIONS.
Hazardous Decomposition Products:BY HIGH HEAT & FIRE: CARBON DIOXIDE,
    CARBON MONOXIDE, HYDROGEN FUMES, SMOKE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:FOLLOW ALL FEDERAL, STATE & LOCAL ENVIRONMENTAL
    CONTROL REGULATIONS. INCINERATION OF MATERIAL IS PREFERRED METHOD.
    CONTAINERS MUST BE HANDLED W/CARE DUE TO FLAMMABLE RESIDUE. RCRA
    STATUS:SINCE THESE P RODS ARE IGNITABLE, THEY ARE HAZ WHEN
    DISCARDED.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.